9.10.11.4. Firewalls in Detached garages

(1) Where a garage is detached from the dwelling unit but attached to another garage on the adjacent property, the party wall so formed shall be constructed as a fire separation having a fire-resistance ratingof not less than 45 min.

Note: On July 1, 2017, Sentence 9.10.11.4.(1) of Division B of the Regulation is amended by striking out "Where a garage is detached from the dwelling unit" at the beginning and substituting "Where a garage is detached from thehouse or the individual dwelling unit it serves". (See: O. Reg. 139/17, s. 107)

9.10.12. Prevention of Fire Spread at exterior Walls and Between Storeys

In Plain Language

Firewalls in detached garages have adjusted requirements set out in this article, reflecting the smaller scale and lower occupancy of these accessory structures.