The Ontario Building Code | Exposure

9.26.9.6. Exposure

(1) The exposure of wood roof shingles shall conform to Table 9.26.9.6.

Table 9.26.9.6.
Exposure of wood Shingles

Forming Part of Sentence 9.26.9.6.(1)

Item

Column 1

Column 2

Column 3

Column 4

Column 5

Column 6

Column 7

Roof Slope

Maximum Exposure, mm

No. 1 or A Grade Length of Shingle, mm

No. 2 or B Grade Length of Shingle, mm

400

450

600

400

450

600

1.

<1 in 3

100

115

165

90

100

140

2.

≥1 in 3

125

140

190

100

115

165

In Plain Language

Wood shingles or shakes must be installed with the exposure (visible portion) set out in this article, balancing weather protection with material coverage.

This is a plain-language summary of the 2012/2017 Ontario Building Code text above, for general understanding only and not a substitute for the Code. Always confirm current requirements against the 2024 edition (O.Reg. 163/24) or a qualified professional before construction.