3.2.3.10. Unlimited Unprotected Openings

(1) An exposing building face of an open-air storey in a storage garageis permitted to have unlimited unprotected openingsprovided it has a limiting distance not less than 3 m.

(2) The exposing building face of a storey that faces a streetand is at the same level as the street is permitted to have unlimited unprotected openings if the limiting distance is not less than 9 m.

In Plain Language

This clause addresses the spatial separation requirements for a building wall located directly on, or very close to, the property line, generally requiring such walls to have a high fire-resistance rating and little to no unprotected openings given the minimal limiting distance available.

This is a plain-language summary of the 2012/2017 Ontario Building Code text above, for general understanding only and not a substitute for the Code. Always confirm current requirements against the 2024 edition (O.Reg. 163/24) or a qualified professional before construction.