The Ontario Building Code | Copper Tube

7.2.7.4. copper Tube

(1) copper tube in a plumbing system shall,

(a) be certified to ASTM B88, "Seamless copper Water tube", or

(b) comply with ASTM B306, "copper Drainage tube (DWV)".

(2) The use of copper tube shall conform to Table 7.2.7.4.

Table 7.2.7.4.
Permitted Use of copper Tube and pipe

Forming Part of Sentence 7.2.7.4.(2)

Item

Column 1

Column 2

Column 3

Column 4

Column 5

Column 6

Column 7

Column 8

Type of copper Tube or pipe

water Distribution System

building Sewer

drainage System

venting ="http://thehandyforce.com/interior/bathroom-renovations/" title ="Toronto Bathroom renovation inspiration">venting System

Under ground

Above ground

Under ground

Above ground

Under ground

Above ground

1.

K & L hard

N

P

P

P

P

P

P

2.

K & L soft

P

P

N

N

N

N

N

3.

M hard

N

P

N

N

P

N

P

4.

M soft

N

N

N

N

N

N

N

5.

DWV

N

N

N

N

P

N

P

Notes to Table 7.2.7.4.:

P — Permitted

N — Not Permitted

(3) copper tube used in a plumbing applianceshall conform to,

(a) ASTM B88, "Seamless copper Water tube", or

(b) ASTM B68 / B68M, "Seamless copper Tube, Bright Annealed".

(4) Type K or L copper tube shall be used for the potablewater side of a heat exchanger in a pre-engineered wastewater heat recovery system.

In Plain Language

Copper tube used in a plumbing system must be certified to either the seamless copper water tube standard or the copper drainage tube standard, with its specific use governed by a dedicated application table.

This is a plain-language summary of the 2012/2017 Ontario Building Code text above, for general understanding only and not a substitute for the Code. Always confirm current requirements against the 2024 edition (O.Reg. 163/24) or a qualified professional before construction.