Notice: This site currently shows the 2012/2017 edition of the Ontario Building Code. The current legally effective code is the 2024 edition (O.Reg. 163/24), in effect since January 1, 2025. Confirm current requirements at ontario.ca.

The Ontario Building Code | Structural Sufficiency of Glass

9.6.1.3. Structural Sufficiency of glass

(1) glass shall be designed in conformance with CAN/cgsb-12.20-M, "Structural design of glass for buildings".

(2) The maximum area of individual panes of glass for doors shall conform to Table 9.6.1.3.

Table 9.6.1.3.
Maximum glass Area for doors

Forming Part of Sentence 9.6.1.3.(2)

Item

Column 1

Column 2

Column 3

Column 4

Column 5

Column 6

Column 7

Column 8

glass Thickness, mm

Maximum glass Area, m2

Type of glass

Annealed

Annealed Multiple-Glazed Factory-Sealed Units

Laminated

wireref ="http://thehandyforce.com/electrical/" title ="Electricians in East York">wired

Heat Strengthened

Fully Tempered

Fully Tempered Multiple-Glazed Factory-Sealed Units

1.

3

0.50

0.70

(1)

(1)

1.00

1.00

2.00

2.

4

1.00

1.50

(1)

(1)

1.50

4.00

4.00

3.

5

1.50

1.50

(1)

(1)

1.50

No limit

No limit

4.

6

1.50

1.50

1.20

1.00

1.50

No limit

No limit

Notes to Table 9.6.1.3.:

(1) Not generally available.

In Plain Language

Glass must have adequate structural sufficiency for its intended use, as set out in this article, ensuring it can withstand the wind, impact, or other loads it will be exposed to.

This is a plain-language summary of the 2012/2017 Ontario Building Code text above, for general understanding only and not a substitute for the Code. Always confirm current requirements against the 2024 edition (O.Reg. 163/24) or a qualified professional before construction.