The Ontario Building Code | Lapped Strip Siding

9.27.8.5. Lapped Strip Siding

(1) Plywood applied in horizontal lapped strips shall have not less than a 2 mm gap provided at the butted ends, which shall be caulked.

(2) The horizontal joints of siding described in Sentence (1) shall be lapped not less than 25 mm.

(3) Wedges shall be inserted under all vertical butt joints and at all corners when horizontal lapped plywood is applied without sheathing.

9.27.9. Hardboard

In Plain Language

Lapped strip siding of this material must be installed as set out in this article, an alternative installation pattern to panel cladding.