The Ontario Building Code | Maximum Spacing of Supports

9.29.5.3. Maximum Spacing of supports

(1) Maximum spacing of supports for gypsum board applied as a single layer shall conform to Table 9.29.5.3.

Table 9.29.5.3.
Spacing of supports for gypsum Board

Forming Part of Sentence 9.29.5.3.(1)

Item

Column 1

Column 2

Column 3

Column 4

Column 5

Thickness, mm

Orientation of Board to Framing

Maximum Spacing of supports, mm o.c.

walls

ceilings

Painted Finish

water-Based Texture Finish

1.

gypsum board conforming to Sentence 9.29.5.2.(1) (except Sections 9 and 12 of ASTM C1396 / C1396M)

9.5

Parallel

Perpendicular

406

406

12.7

Parallel

610

406

Perpendicular

610

610

406

15.9

Parallel

610

406

Perpendicular

610

610

610

2.

gypsum board conforming to Clause 9.29.5.2.(1)(c) (only Section 12 of ASTM C1396 / C1396M)

12.7

Parallel

610

406

Perpendicular

610

610

610

In Plain Language

A maximum spacing of supports is set out in this article for this interior finish material, ensuring it doesn't sag or crack between fastening points.

This is a plain-language summary of the 2012/2017 Ontario Building Code text above, for general understanding only and not a substitute for the Code. Always confirm current requirements against the 2024 edition (O.Reg. 163/24) or a qualified professional before construction.