The Ontario Building Code | Maximum Spacing of Supports

9.29.5.3. Maximum Spacing of supports

(1) Maximum spacing of supports for gypsum board applied as a single layer shall conform to Table 9.29.5.3.

Table 9.29.5.3.
Spacing of supports for gypsum Board

Forming Part of Sentence 9.29.5.3.(1)

Item

Column 1

Column 2

Column 3

Column 4

Column 5

Thickness, mm

Orientation of Board to Framing

Maximum Spacing of supports, mm o.c.

walls

ceilings

Painted Finish

water-Based Texture Finish

1.

gypsum board conforming to Sentence 9.29.5.2.(1) (except Sections 9 and 12 of ASTM C1396 / C1396M)

9.5

Parallel

—

—

—

Perpendicular

406

406

—

12.7

Parallel

610

406

—

Perpendicular

610

610

406

15.9

Parallel

610

406

—

Perpendicular

610

610

610

2.

gypsum board conforming to Clause 9.29.5.2.(1)(c) (only Section 12 of ASTM C1396 / C1396M)

12.7

Parallel

610

406

—

Perpendicular

610

610

610

In Plain Language

A maximum spacing of supports is set out in this article for this interior finish material, ensuring it doesn't sag or crack between fastening points.

This is a plain-language summary of the 2012/2017 Ontario Building Code text above, for general understanding only and not a substitute for the Code. Always confirm current requirements against the 2024 edition (O.Reg. 163/24) or a qualified professional before construction.