3.2.3.5. wall with Limiting Distance Less Than 1.2 m
(1) openings="http://thehandyforce.com/windows/" title ="Window installer in Toronto">openings in a wall that has a limiting distanceless than 1.2 m shall be protected by closureswhose fire-protection rating is in conformance with the fire-resistance rating required for the wall.
(2) wireref ="http://thehandyforce.com/electrical/" title ="Electricians in East York">wired glass or glass block shall not be used for a closure referred to in Sentence (1).
In Plain Language
Where the calculated unprotected opening percentage would be exceeded, this clause allows compensating by installing closures, wired glass, or sprinkler protection at the wall so the effective fire risk still meets the Table 3.2.3.1 limit.